Conversion Kits for 5-5.5KW Honda Generator to use Propane Gas

Conversion Kits for 5-5.5KW Honda Generator to use Propane Gas
上一个
下一个

8DY0004

Conversion Kits for 5-5.5KW Honda Gasoline Generator to use Propane LPG Gas 

With this conversion kits installed, the gasoline generator will be able to use propane gas or methane nature gas without any influence on original gasoline system. This kits is for low pressure gas only, like home used propane gas.

For Honda gasoline generators mainly, and please note it's your responsibility to make sure you can use this conversion kits in your local area.

The conversion kits (weigh 0.7kg) consists of a Zero pressure regulator and a gas carburetor; Zero pressure regulator,  reduce the propane gas or nature gas from high to low and stable pressure before going to gas carburetor then to engine. 

When generator stop working, the zero pressure regulator shut off gas supply also, so it's safe, you no need to worry that gas still going to engine after it died off.

After converted, generator power do not change. When working on propane gas, power depends on generator quality and the gas quality.
For more information please contact us.


How to convert KW to Kva?

When starting from propane gas, make sure no petrol left in the carburetor, or generator will not work right: In the below video, generator first start from petrol then start from propane gas, generator do not work right until the people pour-out all the remain petrol from carburetor and start from propane again. 


 

 

 



User Instruction:
New system is without engine oil, please feed 0.9L before using.


Ways to start generator:
- Start from propane gas:
1. Close petrol switch (Make sure no petrol left in the carburetor)
2. Open propane gas switch.
3. Shut off choke valve switch, pull 3 to 4 times, the
 choke valve open to middle then open in full; when engine be hot, it will open and start directly.
4. Turn on power switch
5. Pull starter rope 4-5times(Choke valve shut off or open to middle)/(key)generator start
6. After started, open 
choke valve switch on the carburetor mixer device
7. Generator start normally

Generator shut off steps: First shut off propane gas tank switch, then shut off generator switch.


 

- Start from petrol:
1. Shut off propane gas

2. Open petrol
3. Shut off
 choke valve switch on petrol carburetor
4. Turn on power switch
5. Pull starter rope several times, generator start

6. After started, open choke valve switch on the carburetor mixer device
7. Generator start normally


Warning:
1. Do not use indoor, if had to, make sure ventilation be good
2. Do not use when inlet gas pressure too high or too low, working pressure should be within 2.8 to 4.8
3. Do not sure when there be gas leakage from gas tank outlet connection port or pipe gas connection
4. Do not place the gas tank upside down, to prevent gas impurity getting into gas system


 